Diagnostics (Basel) ; 14(6)2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38535013

RESUMEN

BACKGROUND: Few studies have evaluated digital morphology (DM) analyzers on body fluids (BF). We evaluated the performance of a DM analyzer, Sysmex DI-60 (Sysmex, Kobe, Japan) for white blood cell (WBC) differentials in BF samples. METHODS: In five BF samples (two pleural fluids and three ascites) containing a single, dominant cell type (>80%, neutrophils, lymphocytes, macrophages, abnormal lymphocytes, and malignant cells in each sample), we evaluated the precision of the DI-60 and compared the WBC differentials and turnaround times (TAT) between DI-60 and manual counting. RESULTS: The precision of the DI-60 pre-classification and verification was excellent (%CV, 0.01-3.16%). After verification, the DI-60 showed high sensitivity, specificity, and efficiency (ranges: 90.8-98.1%, 96.8-97.9%, and 92.5-98.0%, respectively) for the dominant cell types in neutrophil- and lymphocyte-dominant samples. For all samples, the DI-60 and manual counting showed high correlations for major cell types (neutrophils, lymphocytes, macrophages, and others, r = 0.72 to 0.94) after verification. The agreement between the pre-classification and verification of the DI-60 was strong in the neutrophil-dominant sample (κ = 0.81). The DI-60 showed a significantly longer TAT (min: s) than manual counting for all samples (median TAT/slide: 6:28 vs. 1:53, p < 0.0001), with remarkable differences in abnormal lymphocyte- and malignant cell-dominant samples (21:05 vs. 2:06; 12:34 vs. 2:25). CONCLUSIONS: The DI-60 may provide reliable data in neutrophil- and lymphocyte-dominant BF samples. However, it may require longer times and higher workloads for WBC differentials especially in BF samples containing atypical cells. Further improvement would be needed before applying DM analyzers for routine clinical practice in BF analysis.

2.
Clin Lab ; 70(3)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38469788

RESUMEN

BACKGROUND: There is little data about the performance of multiplex rapid antigen tests (RATs) on the detection of SARS-CoV-2, influenza A (Flu A), and influenza B (Flu B). This study is to evaluate the performance of Panbio COVID-19/Flu A&B rapid panel (Abbott Diagnostics, Korea) and analyze the factors influencing its sensitivity. METHODS: Nasopharyngeal swabs were collected and stored at the Korea University Anam hospital. In total, 400 residual samples from nasopharyngeal swabs were examined. The diagnostic accuracy of RAT was compared to that of RT-qPCR using the Allplex SARS-CoV-2/FluA/FluB/RSV Assay (Seegene, Seoul, South Korea). RESULTS: Panbio COVID-19/Flu A&B rapid panel showed the sensitivities of 88.0%, 92.0%, and 100% for SARS-CoV-2, Flu A, and Flu B, respectively, and specificities of 100% for all. The agreements with previously licensed single-plex RATs were shown to be high. In the analysis of variables affecting sensitivity, inappropriate sampling time after symptom onset (STASO) and high cycle threshold (Ct value) were shown to negatively affect the sensi-tivity. CONCLUSIONS: In conclusion, the multiplex RAT is useful for diagnosing SARS-CoV-2 and Flu A/B, but more clinical studies are needed.


Asunto(s)
COVID-19 , Virus de la Influenza A , Gripe Humana , Humanos , Gripe Humana/diagnóstico , SARS-CoV-2 , Virus de la Influenza B/genética , COVID-19/diagnóstico , Nasofaringe , Sensibilidad y Especificidad
3.
Diagnostics (Basel) ; 13(24)2023 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-38132272

RESUMEN

We evaluated the performance of SARS-CoV-2 assays in the vaccinated group using receptor-binding domain antibody assays (RBD Ab assay), neutralizing antibody assay (nAb assay), and interferon-gamma release assay (IGR assay). We also compared the performance of the SARS-CoV-2 assays based on vaccine type in a large population. We collected 1851 samples from vaccinated individuals with vector, mix-and-match (MM), and mRNA vaccines. The performance of the RBD Ab assays was assessed by SARS-CoV-2 IgG II Quant (Abbott Laboratories, Sligo, Ireland), SARS-CoV-2 IgG (Beckman Coulter, CA, USA), and anti-SARS-CoV-2 S (Roche Diagnostics GmbH, Mannheim, Germany). The nAb assay was assessed by cPass SARS-CoV-2 neutralization antibody detection kits (GenScript, NJ, USA). The IGR assay was assessed by QuantiFERON (Qiagen, Venlo, The Netherlands). Median values of the RBD Ab assays and nAb assay sequentially increased after the first and second vaccinations. RBD Ab assays and nAb assay showed very strong correlations. The median values of the RBD Ab, nAb, and IGR were higher in the mRNA vaccine group than in the vector and MM vaccine groups. The agreement and correlation among the RBD Ab assays, nAb assay, and IGR assay were higher in the mRNA vaccine group than in the vector and MM vaccine groups. We compared the performance of the RBD Ab assay, nAb assay, and IGR assay based on the vaccine types using the RBD Ab, nAb, and IGR assays. This study provides a better understanding of the assessment of humoral and cellular immune responses after vaccination.

4.
Clin Lab ; 69(9)2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-37702667

RESUMEN

BACKGROUND: Therapeutic drug monitoring (TDM) of antifungal drugs is recommended. LC-MS/MS outperforms bioassay and high-performance liquid chromatography (HPLC) for TDM. In this study, we validated TDM for voriconazole, posaconazole, and itraconazole using HPLC-MS/MS with the multiple reaction monitoring (MRM) method. METHODS: For the validation of LC-MS/MS for antifungal TDM, accuracy, precision, linearity, carryover, lower limit of quantitation (LLOQ), ion suppression, and sample stability tests were performed according to the guidelines of the United States Food and Drug Administration (FDA) and the Clinical and Laboratory Standards Institute (CLSI). RESULTS: The LC-MS/MS triazole method showed that all analytes had biases less than 8.9% and coefficients of variation (CV) less than 7.7%. The linearity was validated over the ranges of 0.20 to 5.86 mg/L for voriconazole, 0.12 to 4.96 mg/L for posaconazole, 0.09 to 1.85 mg/L for itraconazole, and 0.12 to 2.38 mg/L for OH-itraconazole. Ion suppression and carryover were negligible. The lower limits of quantitation (LLOQs) for voriconazole, posaconazole, itraconazole, and OH-itraconazole were 0.114 mg/L, 0.206 mg/L, 0.118 mg/L, and 0.065 mg/L, respectively. Voriconazole, posaconazole, itraconazole, and OH-itraconazole can be stored at 4℃ for 4 - 7 days, according to sample stability. Sample preparation took < 15 minutes per batch, and analytical run time was 5 minutes per sample. CONCLUSIONS: We developed and validated a simple, reliable, and quick LC-MS/MS method for triazole antifungal agents TDM suitable for routine hospital practice.


Asunto(s)
Antifúngicos , Itraconazol , Estados Unidos , Humanos , Cromatografía Líquida de Alta Presión , Voriconazol , Cromatografía Liquida , Espectrometría de Masas en Tándem , Triazoles
5.
Ann Lab Med ; 43(6): 596-604, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37387492

RESUMEN

Background: Several T-cell response assays for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are available; however, their comparability and correlations with antibody responses remain unclear. We compared four SARS-CoV-2 T-cell response assays and two anti-SARS-CoV-2 spike antibody assays. Methods: We enrolled 89 participants who had received a booster dose of the BNT162b2 vaccine after two doses of the ChAdOx1 or BNT162b2 vaccine. Fifty-six participants without breakthrough infection (BI) (ChAdOx1/BNT162b2 group: N=27; BNT162b2 group: N=29) and 33 with BI were included. We evaluated two whole-blood interferon-gamma release assays (IGRAs) (QuantiFERON and Euroimmun), T-SPOT.COVID, an in-house enzyme-linked immunospot (ELISPOT) assay (targeting the spike and nucleocapsid peptides of wild-type and Omicron SARS-CoV-2), Abbott IgG II Quant, and Elecsys Anti-S, using Mann-Whitney U, Wilcoxon signed-rank, and Spearman's correlation tests. Results: The correlations between the IGRAs and between the ELISPOT assays (ρ=0.60-0.70) were stronger than those between the IGRAs and ELISPOT assays (ρ=0.33-0.57). T-SPOT.COVID showed a strong correlation with Omicron ELISPOT (ρ=0.70). The anti-spike antibody assays showed moderate correlations with T-SPOT.COVID, Euroimmun IGRA, and ELISPOT (ρ=0.43-0.62). Correlations tended to be higher in the BI than in the noninfected group, indicating that infection induces a stronger immune response. Conclusions: T-cell response assays show moderate to strong correlations, particularly when using the same platform. T-SPOT.COVID exhibits potential for estimating immune responses to the Omicron variant. To accurately define SARS-CoV-2 immune status, both T-cell and B-cell response measurements are necessary.


Asunto(s)
Vacuna BNT162 , COVID-19 , Humanos , Infección Irruptiva , SARS-CoV-2 , Linfocitos T , Anticuerpos Antivirales
7.
Diagnostics (Basel) ; 13(2)2023 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-36673069

RESUMEN

Soluble suppression of tumorigenesis-2 (sST2) is an emerging biomarker for sepsis as well as for heart failure. We investigated the prognostic utility of sST2 for predicting clinical outcomes in hospitalized coronavirus disease 2019 (COVID-19) patients. In a total of 52 hospitalized COVID-19 patients, sST2 levels were measured using the ichroma ST2 assay (Boditech Med Inc., Chuncheon-si, Gang-won-do, Republic of Korea). Clinical outcomes included intensive care unit (ICU) admission, ventilator use, extracorporeal membrane oxygenation (ECMO) use, and 30-day mortality. sST2 was analyzed according to clinical outcomes. sST2, sequential organ failure assessment (SOFA) score, critical disease, and 4C mortality score were compared using the receiver operating characteristic (ROC) curve and Kaplan−Meier methods for clinical outcomes. The sST2 level differed significantly according to ICU admission, ventilator use, ECMO use, and 30-day mortality (all p < 0.05). On ROC curve analysis, sST2 predicted ICU admission, ventilator use, ECMO use, and 30-day mortality comparable to SOFA score but significantly better than critical disease. sST2 predicted ICU admission, ventilator use, and ECMO use significantly better than the 4C mortality score. On Kaplan−Meier survival analysis, hazard ratios (95% confidence interval) were 8.4 (2.7−26.8) for sST2, 14.8 (3.0−71.7) for SOFA score, 1.8 (0.5−6.5) for critical disease, and 11.7 (3.4−40.1) for 4C mortality score. This study demonstrated that sST2 could be a useful biomarker to predict ICU admission, ventilator use, ECMO use, and 30-day mortality in hospitalized COVID-19 patients. sST2 may be implemented as a prognostic COVID-19 biomarker in clinical practice.

8.
J Clin Med ; 12(2)2023 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-36675387

RESUMEN

ABO incompatibility is not considered a contraindication for hematopoietic stem cell transplantation (HSCT). We hypothesized that recipient-derived isoagglutinin (RDI) levels could play a critical role in clinical outcomes. In this study, we compared clinical outcomes such as survival, GVHD, infection, relapse, transfusion, and engraftment, among ABO-compatible patients (ABOc), ABO-incompatible patients (ABOi) with low RDI, and ABOi patients with high RDI. The ABOi with high RDI group was defined as recipients with more than 1:16 RDI levels. We analyzed 103 recipients (ABOc, 53; ABOi with low RDI, 36; ABOi with high RDI, 14). The ABOi with high RDI group showed a decreased 1-year survival and increased acute GVHD grade IV and RBC transfusion (p = 0.017, 0.027, and 0.032, respectively). The ABOi with high RDI group was an independent risk factor for increased death, RBC transfusion, and poor platelet (PLT) engraftment (odds ratio (OR) = 3.20, p = 0.01; OR = 8.28, p = 0.02; OR = 0.18, p = 0.03, respectively). The ABOi with high RDI group showed significantly delayed PLT engraftment. In conclusion, this is the first study underscoring high RDI levels as a marker predicting unfavorable outcomes in ABOi HSCT.

9.
Ann Lab Med ; 43(3): 290-294, 2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-36544341

RESUMEN

While numerous studies have evaluated humoral responses to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccines, data on the cellular responses to these vaccines remain sparse. We evaluated T cell responses to ChAdOx1-nCoV-19 and BNT162b2 vaccinations using an interferon gamma (IFN-γ) release assay (IGRA). ChAdOx1-nCoV-19- and BNT162b2-vaccinated participants initially showed stronger T cell responses than unvaccinated controls. The T cell response decreased over time and increased substantially after the administration of a BNT162b2 booster dose. Changes in the T cell response were less significant than those in the anti-receptor-binding domain IgG antibody titer. The study results can serve as baseline data for T cell responses after SARS-CoV-2 vaccination and suggest that the IGRA can be useful in monitoring immunogenicity.


Asunto(s)
COVID-19 , ChAdOx1 nCoV-19 , Humanos , Vacuna BNT162 , Vacunas contra la COVID-19 , COVID-19/prevención & control , SARS-CoV-2 , Vacunación , Anticuerpos Antivirales
10.
Clin Chem Lab Med ; 61(1): 133-141, 2023 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-36306547

RESUMEN

OBJECTIVES: CellaVision DC-1 (DC-1, Sysmex, Kobe, Japan) is a newly launched digital morphology analyzer that was developed mainly for small to medium-volume laboratories. We evaluated the precision, qualitative performance, comparison of cell counts between DC-1 and manual counting, and turnaround time (TAT) of DC-1. METHODS: Using five peripheral blood smear (PBS) slides spanning normal white blood cell (WBC) range, precision and qualitative performance of DC-1 were evaluated according to the Clinical and Laboratory Standards Institute (CLSI) EP15-A3, EP15-Ed3-IG1, and EP12-A2 guidelines. Cell counts of DC-1 and manual counting were compared according to the CLSI EP 09C-ED3 guidelines, and TAT of DC-1 was also compared with TAT of manual counting. RESULTS: DC-1 showed excellent precision (%CV, 0.0-3.5%), high specificity (98.9-100.0%), and high negative predictive value (98.4-100.0%) in 18 cell classes (12 WBC classes and six non-WBC classes). However, DC-1 showed 0% of positive predictive value in seven cell classes (metamyelocytes, myelocytes, promyelocytes, blasts, plasma cells, nucleated red blood cells, and unidentified). The largest absolute mean differences (%) of DC-1 vs. manual counting was 2.74. Total TAT (min:s) was comparable between DC-1 (8:55) and manual counting (8:55). CONCLUSIONS: This is the first study that comprehensively evaluated the performance of DC-1 including its TAT. DC-1 has a reliable performance that can be used in small to medium-volume laboratories for assisting PBS review. However, DC-1 may make unnecessary workload for cell verification in some cell classes.


Asunto(s)
Leucocitos , Humanos , Recuento de Leucocitos , Recuento de Células Sanguíneas , Recuento de Eritrocitos , Valores de Referencia , Reproducibilidad de los Resultados
11.
Clin Lab ; 68(12)2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-36546753

RESUMEN

BACKGROUND: This study aimed to develop and validate a U-HPLC-MS/MS method for simultaneous determination of four immunosuppressants in human whole blood. METHODS: The method was based on the injection of 20 µL of calibrators and controls pretreated with the liquid phase extraction method for chromatography separation and mass spectrometry determination. LPE offline was performed by adding 0.1 mol/L ZnSO4 and acetonitrile, while separation of target compounds was achieved within 2.5 minutes by a Zorbax Eclipse XDB-C8 column using ammonium acetate and ACN mixed with formic acid as solvents. RESULTS: The assay offers ng/mL detection limits (from 1.1 to 12.4 ng/mL), accuracy (% deviation from -4.4% to 5.6%), precision (CV less than 15% at all QC levels), and linearity (from 23.4 to 948 ng/mL for CsA, from 2.11 to 45.5 ng/mL for TAC, SIR and EVR). The recovery and matrix results were acceptable, and the carryover was less than 1%. The results of method comparison show that IA-based methods overestimated the concentration of drugs compared with the MS-based method. Comparing our MS-based method with external LC-MS/MS showed that the results were within 2 SDs. CONCLUSIONS: We have developed a reliable assay for the analysis of CsA, TAC, SIR and EVR in whole blood using U-HPLC-MS/MS.


Asunto(s)
Inmunosupresores , Espectrometría de Masas en Tándem , Humanos , Cromatografía Líquida de Alta Presión , Espectrometría de Masas en Tándem/métodos , Cromatografía Liquida/métodos
12.
Medicina (Kaunas) ; 58(10)2022 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-36295478

RESUMEN

Background: Krebs von den Lungen 6 (KL-6) is a novel biomarker for interstitial lung disease, and it reflects acute lung injury. We explored the usefulness of KL-6 to predict clinical outcomes in hospitalized coronavirus disease 2019 (COVID-19) patients. Methods: In a total of 48 hospitalized COVID-19 patients, KL-6 levels were measured using the HISCL KL-6 assay (Sysmex, Kobe, Japan) with the HISCL 5000 automated analyzer (Sysmex). Clinical outcomes (intensive care unit [ICU] admission, ventilator use, extracorporeal membrane oxygenation [ECMO] use, and 30-day mortality) were analyzed according to KL-6 percentiles. Age, initial KL-6 level, Charlson comorbidity index (CCI), and critical disease were compared using the receiver operating characteristic (ROC) curve and Kaplan-Meier methods for clinical outcomes. Results: KL-6 quartiles were associated with ICU admission, ventilator use, and ECMO use (all p < 0.05), except 30-day mortality (p = 0.187). On ROC curve analysis, initial KL-6 level predicted ICU admission, ventilator use, and ECMO use significantly better than age, CCI, and critical disease (all p < 0.05); age, initial KL-6 level, CCI, and critical disease predicted 30-day mortality comparably. On Kaplan−Meier survival analysis, hazard ratios (95% confidence interval) were 4.8 (1.2−19.3) for age, 4.7 (1.1−21.6) for initial KL-6 level, 3.9 (0.9−16.2) for CCI, and 2.1 (0.5−10.3) for critical disease. Conclusions: This study demonstrated that KL-6 could be a useful biomarker to predict clinical outcomes in hospitalized COVID-19 patients. KL-6 may contribute to identifying COVID-19 patients requiring critical care, including ICU admission and ventilator and/or ECMO use.


Asunto(s)
COVID-19 , Enfermedades Pulmonares Intersticiales , Humanos , Preescolar , COVID-19/terapia , Curva ROC , Biomarcadores , Japón/epidemiología
13.
Diagnostics (Basel) ; 12(9)2022 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-36140614

RESUMEN

Presepsin is an early indicator of infection, and Krebs von den Lungen 6 (KL-6) and Surfactant Protein A (SP-A) are related to the pathogenesis of pulmonary infection and fibrosis. This study aimed to establish reference intervals (RIs) of presepsin, KL-6, and SP-A levels and to evaluate the possible influence of neonatal and maternal factors on presepsin, KL-6, and SP-A levels in umbilical cord blood (UCB). Among a total of 613 UCB samples, the outliers were removed. The RIs for presepsin, KL-6, and SP-A levels were defined using non-parametric percentile methods according to the Clinical and Laboratory Standards Institute guidelines (EP28-A3C). These levels were analyzed according to neonatal and maternal factors: neonatal sex, gestational age (GA), birth weight (BW), Apgar score, delivery mode, the presence of premature rupture of membranes (PROM), gestational diabetes mellitus (GDM), and pre-eclampsia. Presepsin, KL-6, and SP-A levels showed non-parametric distributions and left-skewed histograms. The RIs of presepsin, KL-6, and SP-A levels were 64.9-428.3 pg/mL, 43.0-172.0 U/mL, and 2.1-36.1 ng/mL, respectively. Presepsin, KL-6, and SP-A levels did not show significant differences according to sex, GA, BW, Apgar score, delivery mode, PROM, GDM, and pre-eclampsia. The median level and 97.5th centile RI of KL-6 showed a slight increase with increased GA. We established RIs for presepsin, KL-6, and SP-A levels in large-scaled UCB samples. Further investigation would be needed to determine the clinical significance.

14.
Microbiol Spectr ; 10(4): e0249521, 2022 08 31.
Artículo en Inglés | MEDLINE | ID: mdl-35946811

RESUMEN

We investigated how differences in age, sex, or vaccine type can affect humoral and cellular immune responses after vaccination with vector (ChAdOx1 nCoV-19), mix-and-match (first, ChAdOx1 nCoV-19, and second, BNT162b2), or mRNA (BNT162b2 or mRNA-1273) vaccines against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Venous blood was collected from 573 subjects (vector, 396; mix-and-match, 96; and mRNA, 81) before the first vaccination (T0), 7 to 8 weeks (vector) or 3 to 4 weeks (mRNA) after the first vaccination (T1), and 3 to 4 weeks after the second vaccination (T2). The humoral and cellular immune responses were evaluated using Elecsys anti-SARS-CoV-2 (Roche), Alinity SARS-CoV-2 IgG II Quant (Abbott), cPass SARS-CoV-2 neutralization antibody detection (GenScript), and QuantiFERON SARS-CoV-2 (Qiagen) kits. At T1, the levels of the receptor-binding domain antibodies (RBD Ab) and neutralizing antibodies (NAb) decreased with aging, but interferon gamma release (IGR) levels increased. The RBD Ab, NAb, and IGR levels were higher in females than in males at T1 and T2. The NAb levels were higher in the mix-and-match and mRNA vaccine groups than in the vector vaccine group at T2. The RBD Ab and IGR levels were higher in the mRNA vaccine group than in the vector or mix-and-match vaccine groups at T2. The optimal cutoffs for RBD Ab and NAb, which were used to determine the presence of T cell responses, were 5.7 binding antibody units per milliliter (BAU mL-1) and 12.0 IU mL-1, respectively. Age, sex, and vaccine type affected the humoral and cellular immune responses, and T cell responses could be estimated from RBD Ab and NAb levels. IMPORTANCE There have been few studies that comprehensively evaluated factors affecting immune responses and the correlation between humoral and cellular immune responses after vector, mix-and-match, and mRNA vaccines against SARS-CoV-2. Therefore, we analyzed the effects of age, sex, and the different vaccine regimens on the immune responses to vaccination against SARS-CoV-2. The correlation between humoral and cellular immune responses and the cutoffs were derived for RBD antibodies and neutralizing antibodies to predict the presence of the cellular immune responses. In this comprehensive study, we demonstrated that there were differences in the immune responses induced after vaccination depending on the age and sex of an individual. Among the three vaccine regimens, the mix-and-match and mRNA vaccines induced the most robust immune responses. Finally, the proposed optimal cutoffs for RBD and neutralizing antibodies may be useful for predicting cellular immune responses when assays for cellular immune responses are not available.


Asunto(s)
COVID-19 , Vacunas Virales , Anticuerpos Neutralizantes , Anticuerpos Antivirales , Vacuna BNT162 , COVID-19/prevención & control , Vacunas contra la COVID-19 , ChAdOx1 nCoV-19 , Femenino , Humanos , Inmunidad Celular , Masculino , ARN Mensajero , SARS-CoV-2/genética , Vacunación , Vacunas Sintéticas , Vacunas de ARNm
15.
Diagnostics (Basel) ; 12(6)2022 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-35741159

RESUMEN

BACKGROUND: Immunity against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) wanes over time after vaccination. METHODS: We compared SARS-CoV-2 antibody levels in serial samples from 350 vaccinated individuals at 3 time points (3 weeks after the first or second dose and before the third dose) with 4 assays: GenScript cPASS SARS-CoV-2 neutralization antibody detection kits (cPASS), Siemens SARS-CoV-2 IgG (sCOVG), Abbott SARS-CoV-2 IgG II Quant (CoV-2 IgG II), and an Immuno-On™ COVID-19 IgG test (Immuno-On IgG). Antibody levels by time, concordance between assays, and values from other tests corresponding to the percent inhibition results in cPASS were assessed. RESULTS: The median values at three time points were 49.31%, 90.87%, and 53.38% inhibition for cPASS, 5.39, 13.65, and 2.24 U/mL for sCOVG, 570.25, 1279.65, and 315.80 AU/mL for CoV-2 IgG II, and 223.22, 362.20, and 62.20 relative units (RU) for Immuno-On IgG. The concordance with cPASS at each time point ranged from 0.735 to 0.984, showing the highest concordance in the second sample and lowest concordance in the third in all comparative tests. The values corresponded to 30% inhibition, and the cutoffs of cPASS, were 2.02 U/mL, 258.6 AU/mL, and 74.2 RU for each test. Those for 50%, 70%, and 90% inhibition were 3.16, 5.66, and 8.26 U/mL for sCOVG, while they were 412.5, 596.9, and 1121.6 AU/mL for CoV-2 IgG II and 141.8, 248.92, and 327.14 RU for Immuno-On IgG. CONCLUSIONS: This study demonstrated the dynamic changes in antibody values at different time points using four test systems and is expected to provide useful baseline data for comparative studies and standardization efforts in the future.

16.
Diagnostics (Basel) ; 12(3)2022 Mar 03.
Artículo en Inglés | MEDLINE | ID: mdl-35328181

RESUMEN

Bone marrow fibrosis (BMF) is manually assessed by reticulin and trichrome stain of bone marrow (BM) biopsy and graded on a semi-quantitative scale. Krebs von den Lungen 6 (KL-6) and Mac-2 binding protein glycosylation isomer (M2BPGi) are known to be associated with lung and liver fibrosis, respectively. We explored the usefulness of KL-6 and M2BPGi to assess BMF. A total of 250 patients who underwent BM biopsy with hematologic or non-hematologic diseases were included, and 42 patients with lung and liver diseases were excluded. The patients' data, including age, sex, diagnosis, white blood cell, hemoglobin (Hb), platelet, and lactate dehydrogenase (LDH) were collected. Measured KL-6 and M2BPGi levels were compared with reticulin grade (RG) (grade 0-3). KL-6 levels were significantly elevated with an increase in RG, but M2BPGi did not show a significant difference. Hb, LDH, or KL-6 were independent predictors for BMF (odds ratio: 1.96, 2.26, 2.91, respectively), but showed poor predictive ability (area under the curve [AUC] 0.62, 0.61, 0.60, respectively). The combination of Hb, LDH, and KL-6 showed a significantly improved predictive ability for BMF (AUC 0.73; integrated discrimination improvement 0.057; category-free net reclassification improvement 0.625). This is the first study to evaluate the usefulness of KL-6 for assessing BMF. The combination of Hb, LDH, and KL-6 would be an objective and relevant biomarker approach and be applied to risk stratification for BMF.

18.
Ann Lab Med ; 42(4): 398-405, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35177560

RESUMEN

BACKGROUND: Digital morphology (DM) analyzers are increasingly being used for white blood cell (WBC) differentials. We assessed the laboratory efficiency of the Sysmex DI-60 system (DI-60; Sysmex, Kobe, Japan) in comparison with manual counting in leukopenic samples. METHODS: In total, 40 peripheral blood smear samples were divided into normal, mild leukopenia, moderate leukopenia, and severe leukopenia groups based on WBC count. In each group, the risk and turnaround time (TAT) were compared between DI-60 and manual counting. Risk was determined by failure mode and effect analysis using the risk priority number (RPN) score, and TAT was recorded for the analytical phase. RESULTS: Overall, DI-60 showed a five-fold lower risk (70 vs. 350 RPN) and longer TAT than manual counting. In severe leukopenic samples, DI-60 showed a shorter TAT/slide and a remarkably lower cell count/slide than manual counting. In all samples, the TAT/cell for DI-60 was substantially longer than that for manual counting (DI-60 vs. manual: total, 1.8 vs. 1.0 sec; normal, 1.5 vs. 0.7 sec; mild leukopenia, 1.9 vs. 0.9 sec; moderate leukopenia, 1.8 vs. 1.0 sec; severe leukopenia, 28.8 vs. 19.0 sec). CONCLUSIONS: This is the first comparative assessment of risk and TAT between DI-60 and manual counting in leukopenic samples. DI-60 decreases the laboratory risk and improves patient safety, but requires more time to count fewer cells, especially in severe leukopenic samples. DM analyzers should be applied selectively depending on the WBC count to optimize laboratory efficiency.


Asunto(s)
Leucocitos , Leucopenia , Humanos , Japón , Laboratorios , Recuento de Leucocitos , Leucopenia/diagnóstico
19.
Ann Lab Med ; 42(4): 406-414, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35177561

RESUMEN

BACKGROUND: Biomarkers and clinical indices have been investigated for predicting mortality in patients with coronavirus disease (COVID-19). We explored the prognostic utility of procalcitonin (PCT), presepsin, and the Veterans Health Administration COVID-19 (VACO) index for predicting 30-day-mortality in COVID-19 patients. METHODS: In total, 54 hospitalized COVID-19 patients were enrolled. PCT and presepsin levels were measured using the Elecsys BRAHMS PCT assay (Roche Diagnostics GmbH, Mannheim, Germany) and HISCL Presepsin assay (Sysmex, Kobe, Japan), respectively. The VACO index was calculated based on age, sex, and comorbidities. PCT and presepsin levels and the VACO index were compared using ROC curve, Kaplan-Meier method, and reclassification analysis for the 30-day mortality. RESULTS: ROC curve analysis was used to measure PCT and presepsin levels and the VACO index to predict 30-day mortality; the optimal cut-off values were 0.138 ng/mL for PCT, 717 pg/mL for presepsin, and 12.1% for the VACO index. On Kaplan-Meier survival analysis, hazard ratios (95% confidence interval) were 15.9 (4.1-61.3) for PCT, 26.3 (6.4-108.0) for presepsin, and 6.0 (1.7-21.1) for the VACO index. On reclassification analysis, PCT and presepsin in addition to the VACO index significantly improved the prognostic value of the index. CONCLUSIONS: This study demonstrated the prognostic utility of measuring PCT and presepsin levels and the VACO index in COVID-19 patients. The biomarkers in addition to the clinical index were more useful than the index alone for predicting clinical outcomes in COVID-19 patients.


Asunto(s)
COVID-19 , Sepsis , Biomarcadores , Proteína C-Reactiva/análisis , Humanos , Receptores de Lipopolisacáridos , Fragmentos de Péptidos , Polipéptido alfa Relacionado con Calcitonina , Pronóstico , Curva ROC , SARS-CoV-2
20.
Vox Sang ; 117(3): 399-407, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34318939

RESUMEN

BACKGROUND AND OBJECTIVES: VISION Max (Ortho Clinical Diagnostics, Raritan, NJ) measures anti-A/B isoagglutinin titres using automated column agglutination technology (CAT). We compared tube test (TT) and CAT of VISION Max comprehensively, including failure mode and effect analysis (FMEA), turnaround time (TAT) and cost, and suggested modified CAT (MCAT). MATERIALS AND METHODS: For 100 samples (each 25 for blood type A, B and O with anti-A and anti-B), anti-A/B isoagglutinin titres were measured by TT and CAT (1:2-1:1024 dilution), as well as by MCAT (with agglutination at 1:32 dilution, then perform additional testing from 1:64 to 1:1024). We assessed the agreement and correlation between TT and CAT and compared FMEA (risk priority number [RPN] score), TAT (h:min:sec) and cost (US dollar, US $) among TT, CAT and MCAT. RESULTS: TT and CAT showed overall substantial agreement (k = 0.73) and high correlation (ρ ≥ 0.75) except blood type O with anti-A (ρ = 0.68). Compared with TT, CAT showed lower RPN scores in FMEA and similar TAT and cost (FMEA, 33,700 vs. 184,300; TAT, 15:23:00 vs. 14:26:40; cost, 1377.4 vs. 1312.4, respectively). Regarding FMEA, TAT and cost, MCAT was superior to CAT or TT (43,810; 13:28:00; 899.2, respectively). CONCLUSION: This is the first multidimensional analysis on VISION Max CAT for measuring anti-A/B isoagglutinin titres. The results of anti-A/B isoagglutinin titres by CAT were comparable with those of TT. MCAT would be a safe, time-saving and cost-effective alternative to TT and CAT in high-volume blood bank laboratories.


Asunto(s)
Sistema del Grupo Sanguíneo ABO , Hemaglutininas , Aglutinación , Anticuerpos , Tecnología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...